NORMSERVIS s.r.o.

ASTM E580/E580M-24a

Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions (Includes all amendments and changes 10/30/2024).

STANDARD published on 1.10.2024

English -
Online Secure PDF (80.00 USD)

English -
Standard + Redline - Online secure PDF (96.00 USD)

English -
Print design (80.00 USD)

English -
Print + redline (96.00 USD)


Why Redline?

A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.

With a redline you'll immediately see:

Save Time and Trouble!

With a Redline you no longer have to spend time trying to determine what has changed in the new standard! Redlines save you time and ensure you see what the changes are to the standard.

Price

When you select the "Active + Redline" option you get both documents! Best of all, the cost of an Active + Redline is only slightly more than buying the Active Standard by itself.

View Sample Redline

The information about the standard:

Designation standards: ASTM E580/E580M-24a
Publication date standards: 1.10.2024
The number of pages: 11
Approximate weight : 33 g (0.07 lbs)
Country: American technical standard
Category: Technical standards ASTM

Annotation of standard text ASTM E580/E580M-24a :

This practice covers acoustical ceiling suspension systems and their additional requirements for application in areas subject to light to moderate seismic disturbance such as Uniform Building Code Seismic Zone 2, the BOCA Basic National Building Code where Av is less than 0.20 but greater than 0.10, and the Standard Building Code (SBC) where Av is less than 0.20 but greater than 0.05. This practice also covers areas subject to moderate to severe seismic disturbance such as Uniform Building Code Seismic Zones 3 and 4, the BOCA Basic National Building Code where Av is greater than 0.20, and the SBC where Av is greater than 0.20. The application of this practice is to be determined by local authorities. Current seismic maps published by recognized authorities such as those previously mentioned, as well as related material such as Open File 82-1033 and MS-812 Seismicity Maps, should be consulted. This practice is not intended to stifle research and development of new products or methods which may simplify the application method specified herein. A variation, however, must be substantiated by verifiable engineering data. A ceiling area of 144 ft2 [13m2] or less, surrounded by walls that connect directly to the structure above shall be exempt from this practice.


Keywords:
ceiling suspension, earthquake, seismic, seismic restraint, suspended ceiling,, ICS Number Code 91.060.30 (Ceilings. Floors. Stairs)