ASTM F708-24

Standard Practice for Design and Installation of Rigid Pipe Hangers

STANDARD published on 1.1.2024

English -
PDF - Immediate download (76.00 USD)

English -
PDF + redline - Immediate (91.20 USD)

English -
Print design (76.00 USD)

English -
Print + redline (91.20 USD)


Why Redline?

A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.

With a redline you'll immediately see:

Save Time and Trouble!

With a Redline you no longer have to spend time trying to determine what has changed in the new standard! Redlines save you time and ensure you see what the changes are to the standard.

Price

When you select the "Active + Redline" option you get both documents! Best of all, the cost of an Active + Redline is only slightly more than buying the Active Standard by itself.

View Sample Redline

The information about the standard:

Designation standards: ASTM F708-24
Publication date standards: 1.1.2024
The number of pages: 12
Approximate weight : 36 g (0.08 lbs)
Country: American technical standard
Category: Technical standards ASTM

Annotation of standard text ASTM F708-24 :

This practice covers acceptable methods of fabricating and installing rigid pipe hangers used to support shipboard piping systems, it provides guidance for the design of hanger caps, straps and standoffs, selection of hanger and hanger liner materials, hanger bolting, and hanger spacing. The pipe hanger style includes: split cap hanger, 3strap hanger, welded hanger, U-bolt hanger, J band type hanger, Nelson hanger, clamp hanger assembled with mounting channel, poly-block twin clamp hanger, crimp-on weld stud-type hangers, banded weld stud-type hanger, and poly-block single-clamp hanger. Guidance in determining pipe hanger spacing are provided. Special consideration should be given to areas of concentrated loads, such as risers, valves, or groups of fittings, and to piping configurations that could create rotational forces. Hangers need not be lined unless the hanger and pipe are of dissimilar material. All hanger bolts within tanks or other inaccessible areas shall be secured with lock nuts, lock washers, or by some other means. Pipe hangers and standoffs located in areas subject to corrosion, such as in bilges, ballast tanks, and areas exposed to the weather, should be zinc-plated or blasted and coated with inorganic zinc or coated with the same material as that of the surrounding area. Standoffs fabricated from pipe should not be used within tanks. Consideration should be given to thermal growth of the piping when selecting or locating hangers so as not to overstress the piping or hangers.


Keywords:
design, fabrication, installation, piping systems, rigid pipe hangers,, ICS Number Code 21.060.70 (Clamps and staples)