NORMSERVIS s.r.o.

ASTM E801-21

Standard Practice for Controlling Quality of Radiographic Examination of Electronic Devices

STANDARD published on 1.11.2021

English -
PDF - Immediate download (63.00 USD)

English -
PDF + redline - Immediate (75.60 USD)

English -
Print design (63.00 USD)

English -
Print + redline (75.60 USD)


Why Redline?

A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.

With a redline you'll immediately see:

Save Time and Trouble!

With a Redline you no longer have to spend time trying to determine what has changed in the new standard! Redlines save you time and ensure you see what the changes are to the standard.

Price

When you select the "Active + Redline" option you get both documents! Best of all, the cost of an Active + Redline is only slightly more than buying the Active Standard by itself.

View Sample Redline

The information about the standard:

Designation standards: ASTM E801-21
Publication date standards: 1.11.2021
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM

Annotation of standard text ASTM E801-21 :

This practice is intended to control the quality and repeatability of the radiological examination of electronic devices for internal discontinuities, extraneous material, missing components, crimped or broken wires, and defective solder joints in cavities, in the encapsulating materials, or the boards. However, this practice is not intended to control the acceptability or quality of the electronic devices imaged. The quality of the radiological examination shall be determined by image quality indicators (IQIs), which shall be manufactured from clear acrylic plastic with steel covers serving as shims, lead spheres, gold or tungsten wires, and lead numbers, and shall be permanently identified with the appropriate IQI number. The IQI shall simulate as closely as possible the device being examined. For example, the IQI shall have a radiographic density or grey level nearest to that of the device being examined. Two IQIs shall be used for each radiograph, with each IQI located at diagonally opposite corners of the film, and the radiographic image free of blemishes. To identify the image, in both radiography and radioscopy, a system of positive identification of the image shall be provided, which may include any or all of the following: the name of examining laboratory, the date, the part number, the serial number, the data code, the view, and whether original or subsequent exposure.


Keywords:
electronic devices, IQI´s, radiography, shim, wire ,, ICS Number Code 19.100 (Non-destructive testing)