NORMSERVIS s.r.o.

ČSN EN 13598-2 (646432)

Plastics piping systems for non-pressure underground drainage and sewerage - Unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) - Part 2: Specifications for manholes and inspection chambers

STANDARD published on 1.11.2020

English -
Print design (15.70 USD)

The information about the standard:

Designation standards: ČSN EN 13598-2
Classification mark: 646432
Catalog number: 510734
Publication date standards: 1.11.2020
The number of pages: 36
Approximate weight : 108 g (0.24 lbs)
Country: Czech technical standard
Category: Technical standards ČSN

Annotation of standard text ČSN EN 13598-2 (646432):

This document specifies the definitions and requirements for unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) manholes and inspection chambers intended for non-pressure underground drainage and sewerage systems up to a maximum depth of 6 m from ground level to the invert of the manhole or inspection chamber.
This document covers manholes and inspection chambers, with bases having a flow channel, and their joints to the piping system.
Manholes and inspection chambers are intended to be used in pedestrian or vehicular traffic areas outside the building structure.
NOTE 1 - The intended use in underground installation outside the building structure is reflected in the marking of products by the application area code "U".
NOTE 2 - Products complying with this document can also be used in non-traffic areas.
NOTE 3 - Products complying with this standard can be installed in underground applications without additional static calculation.
NOTE 4 - Shallow chambers are specified in EN 13598-1 [1].
Manholes and inspection chambers complying with EN 13598-2 are made from a prescribed set of components that are manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifier (PP-MD) or polyethylene (PE) and assembled together.
NOTE 5 - The complete manhole or inspection chamber assembly can also include items which are not covered by this document (for example near surface or surface components).
NOTE 6 - Manholes and inspection chambers can be supplied with covers, frame covers and gratings complying with the relevant part of EN 124 [2].
Manholes and inspection chambers complying with EN 13598-2 may be used for storm-water systems.
Manhole and inspection chamber components can be manufactured by various methods e.g. extrusion, injection moulding, rotational moulding, low-pressure moulding or fabricated.
NOTE 7 - Manholes and inspection chambers can be site assembled from different components, but can also be manufactured as a single unit.
NOTE 8 - Manholes and inspection chambers can be subject to national regulations and / or local provisions