IEC 60404-14-ed.1.0

Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method

STANDARD published on 27.6.2002

Spanish -
electronic design (pdf) (119.80 USD)

Spanish -
Print design (119.80 USD)

Spanish -
CD-ROM (121.70 USD)




English and French -
electronic design (pdf) (119.80 USD)

English and French -
Print design (119.80 USD)

English and French -
CD-ROM (121.70 USD)

The information about the standard:

Designation standards: IEC 60404-14-ed.1.0
Publication date standards: 27.6.2002
The number of pages: 27
Approximate weight : 81 g (0.18 lbs)
Country: International technical standard
Category: Technical standards IEC

Annotation of standard text IEC 60404-14-ed.1.0 :

Applicable to all ferromagnetic materials. It is particularly aimed at the measurement of the magnetic dipole moment of permanent magnet (magnetically hard) materials and the measurement of the specific saturation magnetic polarization of cemented carbide materials having a ferromagnetic binder. To describe the general principles of the determination of the magnetic dipole moment of a ferromagnetic material specimen using a detection coil in an open magnetic circuit. By including a means of magnetizing the material to saturation, the saturation magnetic dipole moment can also be determined. In addition, the average magnetic polarization of a test specimen can be derived from the measurement of its magnetic dipole moment and volume. The calibration of magnetic moment coil systems and the measurement of the magnetic dipole moment of feebly magnetic materials can also be determined using this method. Measurements are normally performed at room temperature but measurements at other temperatures can be conducted by heating or cooling the volume occupied by the test specimen within the detection coil. The measurement of remanence, coercivity, maximum energy product and other parameters can be made in a closed magnetic circuit as described in IEC 60404-4 and IEC 60404-5. Measurement of the coercivity HcJ of soft and semi-hard materials can also be performed in an open circuit as described in IEC 60404-7. Applicable a tous les materiaux ferromagnetiques. Elle est en particulier dediee a la mesure du moment magnetique coulombien des materiaux daimant permanent (magnetiquement durs) et a la mesure de la polarisation magnetique de saturation specifique des materiaux consolides par des carbures ayant un liant ferro-magnetique. Decrire les principes generaux de la determination du moment magnetique coulombien dune eprouvette de materiau ferro-magnetique en utilisant une bobine de detection dans un circuit magnetique ouvert. Avec ladjonction dun moyen de magnetisation du materiau a saturation, le moment magnetique coulombien de saturation peut egalement etre determine. En outre, la polarisation magnetique moyenne dune eprouvette peut etre deduite de la mesure de son moment magnetique coulombien et de son volume. Letalonnage de systemes a bobines pour le moment magnetique et la mesure du moment magnetique coulombien de materiaux faiblement magnetiques peuvent egalement etre realises en utilisant cette methode. Les mesures sont normalement executees a la temperature ambiante mais des mesures a dautres temperatures peuvent etre realisees en chauffant ou en refroidissant le volume qui est occupe par leprouvette dans la bobine de detection. La mesure de la remanence, de la coercitivite, du produit maximal denergie et dautres para-metres peut etre faite dans un circuit magnetique ferme comme decrit dans la CEI 60404-4 et dans la CEI 60404-5. La mesure de la coercitivite HcJ des materiaux doux et semi-durs peut egalement etre executee dans un circuit ouvert comme decrit dans la CEI 60404-7.