NORMSERVIS s.r.o.

IEC 60730-2-15-ed.4.0

Automatic electrical controls - Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls

STANDARD published on 10.4.2026

English -
electronic design (pdf) (452.60 USD)

English -
Print design (452.60 USD)

English -
CD-ROM (454.50 USD)




French -
electronic design (pdf) (452.60 USD)

French -
Print design (452.60 USD)

French -
CD-ROM (454.50 USD)




English and French -
electronic design (pdf) (452.60 USD)

English and French -
Print design (452.60 USD)

The information about the standard:

Designation standards: IEC 60730-2-15-ed.4.0
Publication date standards: 10.4.2026
The number of pages: 88
Approximate weight : 295 g (0.65 lbs)
Country: International technical standard
Category: Technical standards IEC

Annotation of standard text IEC 60730-2-15-ed.4.0 :

IEC 60730-2-15:2026 applies to automatic electrical air flow, water flow and water level sensing controls - for use in, on, or in association with boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications; NOTE 1 Throughout this document, the word "equipment" means "appliance and equipment" and "controls" means "automatic electrical air flow, water flow and water level sensing controls". EXAMPLE 1 Water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow and water level sensing controls for swimming pool pumps, water tank pumps, cooling towers, dishwashers, washing machines, air conditioning chillers and ventilation applications. - for building automation within the scope of ISO 16484 series and IEC 63044 series (HBES/BACS); EXAMPLE 2 Independently mounted air flow, water flow and water level sensing controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. - for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; EXAMPLE 3 Controls for commercial boilers, heating and air-conditioning equipment. - that are smart enabled controls; EXAMPLE 4 Smart grid control, remote interfaces/control of energy-consuming equipment including computer or smart phone. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; - utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; - using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; - that are mechanically or electrically operated, responsive to or controlling air flow, water flow and water level; - as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 2 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document applies to - the inherent safety of automatic electrical air flow, water flow and water level sensing controls, and - functional safety of automatic air flow, water flow and water level sensing electrical controls and safety related systems, - controls where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with equipment safety. This document specifies the requirements for construction, operation and testing of automatic electrical air flow, water flow and water level sensing controls used in, on, or in association with an equipment. This document takes into account the response value of an automatic action of a control where such a response value is dependent upon the method of mounting the control. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment standard or as determined by the manufacturer applies. This document does not - apply to air flow, water flow and water level sensing controls intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. However, this document can be applied to evaluate air flow, water flow and water level sensing controls intended specifically for industrial applications in cases where no relevant safety standard exists; - address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system; - apply to pressure sensing controls, the requirements for which are contained in IEC 60730-2-6. This fourth edition cancels and replaces the third edition published in 2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) adoption to IEC 60730-1:2022 with all of its significant changes to IEC 60730-1:2013, IEC 60730-1:2013/AMD1:2015 and IEC 60730-1:2013/AMD2:2020. LIEC 60730-2-15:2026 sapplique aux dispositifs de commande electrique automatiques detecteurs de debit dair, de debit deau et de niveau deau - pour usage dans, sur ou en association avec des chaudieres dont la pression maximale assignee est de 2 000 kPA (20 bar) et des materiels a usage domestique general et analogue, y compris des dispositifs de commande pour le chauffage, lair conditionne et les applications analogues; NOTE 1 Dans le present document, le terme "materiel" signifie "appareil et materiel" et "dispositifs de commande" signifie "dispositifs de commande electrique automatiques detecteurs de debit dair, de debit deau et de niveau deau". EXEMPLE 1 Les dispositifs de commande detecteurs de debit deau et de niveau deau du type a flotteur ou a electrode utilises dans les applications de chaudieres et les dispositifs de commande detecteurs de debit dair, de debit deau et de niveau deau pour les pompes de piscine, les pompes de reservoir deau, les tours de refroidissement, les lave-vaisselles, les machines a laver le linge, les refrigerants de conditionnement dair et les applications de ventilation. - pour lautomatisation des batiments qui relevent du domaine dapplication de la serie ISO 16484 et de la serie IEC 63044 (HBES/BACS); EXEMPLE 2 Dispositifs de commande detecteurs de debit dair, de debit deau et de niveau deau montes independamment, les dispositifs de commande