Residual strength of string insulator units of glass or ceramic material for overhead lines after mechanical damage of the dielectric
STANDARD published on 1.1.1984
Designation standards: IEC/TR 60797-ed.1.0
Publication date standards: 1.1.1984
The number of pages: 15
Approximate weight : 45 g (0.10 lbs)
Country: International technical standard
Category: Technical standards IEC
Applies to string insulator units of the cap and pin type with insulating parts of toughened glass or ceramic material. Note. - The test procedure given in this report is not applicable to ceramic long rod insulators for the reasons given in Appendix A. Annealed glass cap and pin string insulator units are not considered in this report. Has the status of a technical report. Est applicable aux elements de chaine disolateurs du type capot et tige avec partie isolante en verte trempe ou en matiere ceramique. Note. - La procedure dessai decrite dans ce rapport ne sapplique pas aux isolateurs a long fut en ceramique pour les raisons exposees dans lannexe A. Les elements de chaine disolateurs capot et tige en verre recuit ne sont pas pris en consideration dans ce rapport. Cette publication a le statut dun rapport technique.