Standard Specification for Welded Copper Tube
STANDARD published on 1.4.2012
Designation standards: ASTM B447-12
Note: WITHDRAWN
Publication date standards: 1.4.2012
SKU: NS-6731
The number of pages: 9
Approximate weight : 27 g (0.06 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
copper tube, copper welded tube, welded tube , Copper UNS No. C10100, Copper UNS No. C10200, Copper UNS No. C10300, Copper UNS No. C10800, Copper UNS No. C11000, Copper UNS No. C12000, Copper UNS No. C12200, Copper UNS No. C14200, Copper welded tube, UNS C10100 (oxygen-free copper)--pipe/tube, UNS C10200--pipe/tube (seamless/welded), UNS C10300--pipe/tube (seamless/welded), UNS C10800--pipe/tube (seamless/welded), UNS C11000 (electrolytic tough pitch coper (ETP))
| Significance and Use | ||||||||||||||||||||||||||||||
|
For purposes of determining compliance with the specified limits for requirements of the properties listed in the following table and for dimensional tolerances, an observed value or a calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29:
|
||||||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||||||
|
1.1 This specification establishes the requirements for welded copper tube with a longitudinal seam free of filler metal produced from sheet or strip of the following coppers:
1.2 Unless otherwise specified in the contract or purchase order, product furnished of any listed copper, with the exception of copper C11000, shall be considered acceptable. 1.2.1 Copper C11000 welded tube shall not be used in applications where hydrogen embrittlement during heating is a concern. 1.3 Units—Values stated in inch-pound units are to be regarded as standard except for grain size, which is given in SI units. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard. 1.4 The following hazard caveat pertains only to Section 13 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||