Standard Test Methods for Tension Testing Wrought and Cast Aluminum- and Magnesium-Alloy Products (Metric)
STANDARD published on 1.10.2015
Designation standards: ASTM B557M-15
Note: WITHDRAWN
Publication date standards: 1.10.2015
SKU: NS-618465
The number of pages: 16
Approximate weight : 48 g (0.11 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
elongation, strain, stress, tensile strength, tensile testing, yield strength,, ICS Number Code 77.150.10 (Aluminium products),77.150.20 (Magnesium products)
Significance and Use | ||||||||||||||||||
4.1 Tension tests provide information on the strength and ductility of materials under uniaxial tensile stresses. This information may be useful in comparisons of materials, alloy development, quality control, and design under certain circumstances. 4.2 The results of tension tests of specimens machined to standardized dimensions from selected portions of a part or material may not totally represent the strength and ductility properties of the entire end product or its in-service behavior in different environments. 4.3 These test methods are considered satisfactory for acceptance testing of commercial shipments and have been used extensively in the trade for this purpose. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 These test methods cover the tension testing of wrought and cast aluminum- and magnesium-alloy products, with the exception of aluminum foil,2 and are derived from Test Methods E8M, which cover the tension testing of all metallic materials. Note 1: These metric test methods are the equivalents of those
in Test Methods B557, and are
compatible in technical content except for the requirement of
longer gage lengths for round specimens.
Note 2: Foil is sheet metal less than 0.20 mm thick. There is
an overlap in the thickness range 0.15 to 0.20 mm defined for foil
and sheet. Sheet products in this thickness range are supplied to
sheet product specifications and foil products in this thickness
range are supplied to foil product specifications. Exceptions to
the provisions of these test methods may need to be made in
individual specifications or test methods for a particular
material.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|