Standard Specification for Compressed Round Stranded Aluminum Conductors Using Single Input Wire Construction
STANDARD published on 1.10.2015
Designation standards: ASTM B901-04(2015)
Note: WITHDRAWN
Publication date standards: 1.10.2015
SKU: NS-617114
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
aluminum, aluminum stranded conductors, compressed, concentric lay stranded conductors, electrical conductors, reverse concentric, single input wire, SIW, unidirectional, unilay,, ICS Number Code 29.240.20 (Power transmission and distribution lines)
1. Scope | ||||||||||||||||||||||
1.1 This specification covers aluminum 1350-H19 (extra hard), 1350-H16 or -H26 (3/4 hard), 1350-H14 or -H24 (1/2 hard), 1350-H142 or -H242 (1/2 hard), and aluminum alloy 8XXX series as listed in Specification B800 for tempers “O” and H1X or H2X, bare stranded conductors composed of one or more roller shaped or die compressed layers of helically layed wires. The conductors are for general use for electrical purposes (Explanatory Notes 1 and 2). Note 1: For the purposes of this specification, single input
wire (SIW) construction is defined as follows: a stranded conductor
design methodology that varies the number of wires within a range
of conductor sizes in order to permit that range of conductor sizes
to be constructed from a single wire size.
1.2 The SI values for resistivity are regarded as standard. For all other properties, the inch-pound units are regarded as standard and the SI units may be approximate. Note 2: Prior to 1975, aluminum 1350 was designated as EC
aluminum.
Note 3: The aluminum and temper designations conform to ANSI
H35.1. Aluminum 1350 corresponds to Unified Numbering System A91350
in accordance with Practice E527. Aluminum alloys in the 8000 series
correspond to Unified Numbering System A98XXX in accordance with
Practice E527.
Note 4: This specification also permits conductors for use as
covered or insulated electrical conductors.
Note 5: Sealed conductors, which are intended to prevent
longitudinal water propagation and are further covered/insulated,
are also permitted within the guidelines of this
specification.
|
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Historical
1.4.2013
Historical
1.4.2014
Historical
1.10.2011
Historical
1.4.2013
Historical
1.5.2013
Historical
1.1.2013
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-05-01 (Number of items: 2 896 514)
© Copyright 2024 NORMSERVIS s.r.o.