We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Microindentation Hardness of Powder Metallurgy (PM) Materials
STANDARD published on 1.4.2016
Designation standards: ASTM B933-16
Note: WITHDRAWN
Publication date standards: 1.4.2016
SKU: NS-637666
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
Knoop microindentation hardness, microindentation hardness, PM, powder metallurgy, Vickers microindentation hardness,, ICS Number Code 77.160 (Powder metallurgy)
Significance and Use | ||||||
5.1 Microindentation hardness testing provides a measure of the hardness of the microstructural constituents of a porous material. It indicates the hardness the material would have if there were no pores present and the material was tested using macroindentation hardness methods. Loads are limited to a maximum of 200 gf to reduce the likelihood of interference from the porosity. 5.2 Microindentation hardness tests allow the evaluation of specific phases, microstructural constituents, and regions or gradients too small for macroindentation hardness testing. |
||||||
1. Scope | ||||||
1.1 This test method covers the determination of the microindentation hardness of powder metallurgy (PM) materials. The test method differs from the approach used for pore-free materials in terms of the precautions required to deal with the porosity. 1.2 This procedure covers tests made with the Knoop or Vickers indenters under loads in the range from 1 to 200 gf. 1.3 Automated testing is not generally suitable for use with porous PM materials, because acceptable indentations require avoiding placing indentations in the immediate vicinity of a pore, a condition not guaranteed with automated placement of the indentations. Any automated testing shall allow for review of indentations post-test to reject any distorted or unusually large indentations in accordance with 9.4. 1.4 A method for converting the directly measured indentation lengths to other hardness scales, for example, HRC is described in Appendix X1. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||