Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring (Includes all amendments And changes 12/31/2010).
Automatically translated name:
Standard Test Method for Passing Ability of Self-Consolidating Concrete by J-Ring
STANDARD published on 1.6.2009
Designation standards: ASTM C1621/C1621M-09a
Note: WITHDRAWN
Publication date standards: 1.6.2009
SKU: NS-12053
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
halo, j-ring, j-ring flow, passing ability self-consolidating concrete, slump flow, spread, Concrete, J-ring, Self-consolidating concrete, ICS Number Code 91.100.30 (Concrete and concrete products)
| Significance and Use | ||||||||||
|
This test method provides a procedure to determine the passing ability of self-consolidating concrete mixtures. The difference between the slump flow and J-Ring flow is an indication of the passing ability of the concrete. A difference less than 25 mm [1 in.] indicates good passing ability and a difference greater than 50 mm [2 in.] indicates poor passing ability. The orientation of the mold for the J-Ring test and for the slump flow test without the J-Ring shall be the same. This test method is applicable for laboratory use in comparing the passing ability of different concrete mixtures. It is also applicable in the field as a quality control test. |
||||||||||
| 1. Scope | ||||||||||
|
1.1 This test method covers determination of the passing ability of self-consolidating concrete by using the J-Ring in combination with a mold. The test method is limited to concrete with nominal maximum size of aggregate of up to 25 mm [1 in.]. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 The text of this standard references notes that provide explanatory material. These notes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.) |
||||||||||
| 2. Referenced Documents | ||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-06-11 (Number of items: 2 281 927)
© Copyright 2026 NORMSERVIS s.r.o.