We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Specification for Nonreinforced Concrete Irrigation Pipe With Rubber Gasket Joints (Metric)
STANDARD published on 1.9.2011
Designation standards: ASTM C505M-11
Note: WITHDRAWN
Publication date standards: 1.9.2011
SKU: NS-13738
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
absorption, acceptance criteria, concrete, design, drainage, gasket tests, gaskets, hydrostatic, irrigation, joints, manufacture, nonreinforced, pipe, pressure, rubber gaskets, tests, three-edge bearing: Concrete pipe (nonreinforced)--specifications, Watertight joints, Joints (concrete applications)--specifications, Pressure pipelines/piping systems--specifications, Gaskets--specifications, Irrigation piping--specifications
| 1. Scope | |||||||||||||||||||||||||||||||||||||||||||||
|
1.1 This specification covers nonreinforced concrete pipe with rubber gasket joints to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1. 1.2 This specification is the SI counterpart of Specification C505. Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation. TABLE 1 Standard Dimensions, Working Pressures, and Test Requirements
A Thinner walls are not prohibited on pipe units not over 1.22 m in length but the thickness of such walls should be not less than the internal diameter divided by 10. B With the exception of 525 and 600-mm pipe, higher working pressures are not prohibited to be used up to a maximum of 15 m for 150 through 300-mm diameters and 12 m for 375 through 450-mm diameters. In these cases the strength of the pipe shall be increased to give minimum internal hydrostatic test pressures of at least three times the design working pressure when tested as specified in 10.4. C For hydrostatic test requirements, refer to 10.4. |
|||||||||||||||||||||||||||||||||||||||||||||
| 2. Referenced Documents | |||||||||||||||||||||||||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-06-28 (Number of items: 2 284 473)
© Copyright 2026 NORMSERVIS s.r.o.