We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Time of Setting of Hydraulic Cement Mortar by Modified Vicat Needle
STANDARD published on 1.6.2008
Designation standards: ASTM C807-08
Note: WITHDRAWN
Publication date standards: 1.6.2008
SKU: NS-15142
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
hydraulic-cement mortar, time of setting, Vicat needle, expansive, Cement mortars, Hydraulic cement mortar, Modified Vicat needle, Setting time, Vicat needle, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
| Significance and Use | ||||||||||||||||||||||
|
The purpose of this test method is to establish whether or not a cement complies with a specification limit on time of setting. It has been found to be particularly applicable for the determination of the setting time of expansive cements (see Specification C 845). |
||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||
|
1.1 This test method covers the determination of the time of setting of hydraulic cement mortar by means of the modified Vicat needle. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. The use of gloves, protective clothing, and eye protection is recommended. Wash contact area with copious amounts of water after contact. Wash eyes for a minimum of 15 min. Avoid exposure of the body to clothing saturated with the liquid phase of the unhardened material. Remove contaminated clothing immediately after exposure.) 1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. |
||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-07-05 (Number of items: 2 286 116)
© Copyright 2026 NORMSERVIS s.r.o.