Standard Specification for External Sealing Bands for Concrete Pipe, Manholes, and Precast Box Sections
Translate name
STANDARD published on 15.1.2021
Designation standards: ASTM C877-21
Publication date standards: 15.1.2021
SKU: NS-1016983
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
This specification deals with the metric standard for three types of external sealing bands to be used in conjunction with concrete pipe, manholes, and precast box sections. The first type of bands shall be composed of rubber, mastic, and protective film elements, while the second type shall consist of a plastic film, reinforced, rubberized, asphalt, mastic coating with steel straps. The third type shall be composed of a backing band, an applied continuous butyl adhesive coating and an optional release element. All the elements of each type of sealing band shall have physical properties conforming with specified limits as determined through appropriate test methods herein provided.
Keywords:
bands, external, concrete pipe, joints,, ICS Number Code 91.100.50 (Binders. Sealing materials)
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1?This specification covers external sealing bands to be used in conjunction with concrete pipe as defined in Terminology C822 and conforming to Specifications C14, C76, C412, C478/C478M, C506, C507, C655, C985, C1417, and C1433. 1.1.1?Type I, Rubber and Mastic Bands. 1.1.2?Type II, Plastic Film and Mesh Reinforced Mastic Bands. 1.1.3?Type III, Chemically-Bonded Adhesive Butyl Bands. 1.2?This specification is the inch-pound companion to Specification C877M; therefore, no SI equivalents are presented in the specification. Note 1:?This specification covers only the design and material
of the sealing bands. Sealing bands covered by this specification
are adequate, when properly installed, for external hydrostatic
pressures up to 13 psi, (30 ft) without leakage. The amount of
infiltration or exfiltration flow in an installed pipeline is
dependent upon many factors other than the sealing bands; allowable
quantities and suitable testing of the installed pipeline and
system must be covered by other specifications.
1.3?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-05-17 (Number of items: 2 902 148)
© Copyright 2024 NORMSERVIS s.r.o.