We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Specification for Unmodified Poly(Vinylidene Fluoride) (PVDF) Molding Extrusion and Coating Materials
STANDARD published on 10.4.1999
Designation standards: ASTM D3222-99
Note: WITHDRAWN
Publication date standards: 10.4.1999
SKU: NS-22901
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
extrusion materials, fluorohydrocarbon plast, fluoropolymers, molding materials, polyvinylidene fluoride (PVDF), ICS Number Code 83.080.20 (Thermoplastic materials)
| 1. Scope | ||||||||||||||||||||||||||||||||
|
1.1 This specification covers melt processable molding and extrusion materials, as well as coating materials of poly(vinylidene fluoride) fluoroplastic, commonly abbreviated PVDF (or PVF2 in scientific literature). This specification covers thermoplastic resin materials supplied in pellet or powder form. 1.2 This specification applies only to the virgin homopolymer prepared from vinylidene fluoride, not copolymers, reinforced, filled grades or special grades with additives or treatments for modification of attributes. 1.3 The values stated in SI units and the practices of Practice E380 incorporated herein are to be regarded as standard except where common usage or test method specify common units acceptable within Practice E380. 1.4 The tests involved are intended to provide information for specification of unmodified PVDF homopolymer resins. It is not the purpose of this specification to provide engineering data for design purposes. 1.5 PVDF fluoroplastics melt between 156 and 180°C (312 and 356°F) and are thermally stable up to about 370°C (698°F). Note 1-Evolution of corrosive and toxic hydrogen fluoride can occur under certain conditions.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Note 1 and Section 9. Note 2-PVDF exhibits polymorphism. The type and extent of crystalline structure varies with the thermomechanical history of the sample. Specimens prepared by techniques different than prescribed in this specification could have properties that may vary from the values specified. |
||||||||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-08-14 (Number of items: 2 293 479)
© Copyright 2026 NORMSERVIS s.r.o.