We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method
STANDARD published on 15.9.2008
Designation standards: ASTM D4105-96(2008)
Note: WITHDRAWN
Publication date standards: 15.9.2008
SKU: NS-26061
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
aquifer tests, aquifers, confined aquifers, control wells, groundwater, hydraulic properties, observation wells, storage coefficient, transmissivity, unconfined aquifers, Aquifers, Coefficient of storage, Confined aquifers, Control wells, Field testing--ground water/aquifers, Ground water, Hydraulic conductivity/transmissivity, Observation wells, Storativity, Theis methods of analysis, Transmissivity and reflectivity, Unconfined/unconsolidated aquifers
| Significance and Use | ||||||||||||
|
Assumptions: Well discharges at a constant rate, Q. Well is of infinitesimal diameter and fully penetrates the aquifer, that is, the well is open to the full thickness of the aquifer. The nonleaky aquifer is homogeneous, isotropic, and areally extensive. A nonleaky aquifer receives insignificant contribution of water from confining beds. Discharge from the well is derived exclusively from storage in the aquifer. The geometry of the assumed aquifer and well conditions are shown in Fig. 1. Implications of Assumptions: Implicit in the assumptions are the
conditions of radial flow. Vertical flow components are induced by
a control well that partially penetrates the aquifer, that is, not
open to the aquifer through its full thickness. If the control well
does not fully penetrate the aquifer, the nearest piezometer or
partially penetrating observation well should be located at a
distance, r, beyond which vertical flow
components are negligible, where according to Reed (5) This section applies to distance-drawdown
calculations of transmissivity and storage coefficient and
time-drawdown calculations of storage coefficient. If possible,
compute transmissivity from time-drawdown data from wells located
within a distance, r, of the pumped
well using data measured after the effects of partial penetration
have become constant. The time at which this occurs is given by
Hantush (6) by: Fully penetrating observation wells may be placed at less than distance r from the control well. Observation wells may be on the same or on various radial lines from the control well. The Theis method assumes the control well
is of infinitesimal diameter. Also, it assumes that the water level
in the control well is the same as in the aquifer contiguous to the
well. In practice these assumptions may cause a difference between
the theoretical drawdown and field measurements of drawdown in the
early part of the test and in and near the control well. Control
well storage is negligible after a time, t, given by the following equation after weeks
(7).
Application of Theis Nonequilibrium Method to Unconfined Aquifers: Although the assumptions are applicable to confined conditions, the Theis solution may be applied to unconfined aquifers if drawdown is small compared with the saturated thickness of the aquifer or if the drawdown is corrected for reduction in thickness of the aquifer and the effects of delayed gravity yield are small. Reduction in Aquifer Thickness—In an
unconfined aquifer, dewatering occurs when the water levels decline
in the vicinity of a pumping well. Corrections in drawdown need to
be made when the drawdown is a significant fraction of the aquifer
thickness as shown by Jacob (8). The
drawdown, s, needs to be replaced by
s′, the
drawdown that would occur in an equivalent confined aquifer,
where: Gravity Yield Effects—In unconfined
aquifers, delayed gravity yield effects may invalidate measurements
of drawdown during the early part of the test for application to
the Theis method. Effects of delayed gravity yield are negligible
in partially penetrating observation wells at a distance,
r, from the control well, where: after the time, t, as given in the following equation from Neuman
(9):
For fully penetrating observation wells, the effects of delayed yield are negligible at the distance, r, in Eq 11 after one tenth of the time given in the Eq 12.
|
||||||||||||
| 1. Scope | ||||||||||||
|
1.1 This test method covers an analytical procedure for determining transmissivity and storage coefficient of a nonleaky confined aquifer under conditions of radial flow to a fully penetrating well of constant flux. This test method is a shortcut procedure used to apply the Theis nonequilibrium method. The Theis method is described in Test Method D4106. 1.2 This test method is used in conjunction with the field procedure given in Test Method D4050. 1.3 Limitations—The limitations of this test method are primarily related to the correspondence between the field situation and the simplifying assumptions of this test method (see 5.1). Furthermore, application is valid only for values of u less than 0.01 (u is defined in Eq 2, in 8.6). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
| 2. Referenced Documents | ||||||||||||
|
||||||||||||
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-08-21 (Number of items: 2 298 377)
© Copyright 2026 NORMSERVIS s.r.o.