We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable (Includes all amendments And changes 12/31/2010).
Automatically translated name:
Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
STANDARD published on 1.3.2005
Designation standards: ASTM D4566-05e1
Note: WITHDRAWN
Publication date standards: 1.3.2005
SKU: NS-27724
The number of pages: 29
Approximate weight : 87 g (0.19 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
aging, attenuation, attenuation to crosstalk ratio near-end, attenuation to crosstalk ratio far-end, capacitance deviation, capacitance difference, capacitance unbalance pair-to-pair, capacitance unbalance pair-to-ground, capacitance unbalance pair-to-support wire, characteristic impedance, coaxial capacitance, conductor resistance, conductor resistance unbalance, continuity, conversion loss, crosses, crosstalk loss-far end, crosstalk loss-near end, dc proof test, equal level far-end crosstalk
| 1. Scope | ||||||||||||||||||
|
1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product. 1.2 The test methods appear in the following sections of this standard: 1.3 The values stated in inch-pound units are to be regarded as the standard. SI units are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections and . 1.4 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable. 1.5 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections through . |
||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-09-04 (Number of items: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.