We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Polyurethane Raw Materials Determination of Unsaturation of Polyols (Includes all amendments And changes 4/8/2016).
Automatically translated name:
Standard Test Method for Polyurethane Raw Materials Determination of Unsaturation of Polyols
STANDARD published on 1.7.2010
Designation standards: ASTM D4671-05(2010)e1
Note: WITHDRAWN
Publication date standards: 1.7.2010
SKU: NS-28095
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
polyether polyol, polyols, polyurethane raw materials, raw material, titration, unsaturation, Acetic acid release, Carbon-to-carbon unsaturated samples, Methane content, Polyols, Polyurethane raw materials--polyols, Quality control (QC)--plastics, Unsaturation, ICS Number Code 83.040.30 (Auxiliary materials and additives for plastics)
| Significance and Use | ||||||
|
These test methods are suitable for quality control, as specification tests, and for research. Side reactions that form unsaturated compounds in polypropylene oxides produce small amounts of polymers with only one hydroxyl group per chain. These unsaturated polymers lower functionality and molecular weight, while broadening the overall molecular-weight distribution. |
||||||
| 1. Scope | ||||||
|
1.1 These test methods measure unsaturation in polyether polyols. (See Note 1.) 1.1.1 Test Method A, High-Volume Reagent Method—Uses about 50 mL of 0.1 M mercuric acetate reagent in methanol and 15 g or more of sample. These test methods use an indicator for colorimetric determination of an end point. It is recommended for polyols with low values (below 0.01 millequivalents per gram (meq/g)) of unsaturation where large sample sizes are required. 1.1.2 Test Method B, Low-Volume Reagent Method—Uses 2 mL of ca. 0.05 M mercuric acetate reagent in methanol and about 1 g of sample or less. These test methods use a potentiometric determination of an end point. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Note 1—There is no known ISO equivalent to this standard. |
||||||
| 2. Referenced Documents | ||||||
|
Historical
1.4.2007
Historical
15.4.2009
Historical
1.7.2013
Historical
1.11.2007
Historical
1.3.2014
Historical
15.11.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-09-04 (Number of items: 2 300 131)
© Copyright 2026 NORMSERVIS s.r.o.