We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Analysis of Phenol by Capillary Gas Chromatography
Translate name
STANDARD published on 1.11.2021
Designation standards: ASTM D6142-21
Note: WITHDRAWN
Publication date standards: 1.11.2021
SKU: NS-1043792
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
2-methylbenzofuran, acetone, acetophenone, ?-methylstyrene, cumene, gas chromatography, hydroxyacetone, mesityl oxide, phenol, sec-butyl alcohol,, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| Significance and Use | ||||||||||||||||
|
5.1This test method is suitable for setting specifications on phenol and for use as an internal quality control tool where phenol is produced or is used in a manufacturing process. It may also be used in development or research work involving phenol. It is generally applied to determining those commonly occurring impurities such as mesityl oxide, cumene, hydroxyacetone, acetone, ?-methylstyrene, 2-methylbenzofuran, and acetophenone. 5.2Purity is commonly reported by subtracting the determined expected impurities from 100.00. However, a gas chromatographic analysis cannot determine absolute purity if water is present or unknown components are contained within the material being examined. |
||||||||||||||||
| 1. Scope | ||||||||||||||||
|
1.1This test method covers the determination of known impurities in phenol by gas chromatography (GC). It is generally meant for the analysis of phenol of 99.9 % or greater purity. 1.2This test method has been found applicable over impurity concentrations up to 70 mg/kg. Users of this method believe it is linear over a wider range. The limit of detection (LOD) is 1.7 mg/kg and the limit of quantitation (LOQ) is 5.8 mg/kg. Note 1:LOD is defined in 7.1 as part of the method setup. The
values above were calculated based on the ILS data for acetone,
acetophenone, ?-methylstyrene, and 2-methylbenzofuran in Table
3.
1.3In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29. 1.4The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2026-08-18 (Number of items: 2 297 400)
© Copyright 2026 NORMSERVIS s.r.o.