Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water (Includes all amendments and changes 2/9/2017).
Automatically translated name:
Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water
STANDARD published on 15.2.2016
Designation standards: ASTM D6504-11(2016)e1
Publication date standards: 15.2.2016
SKU: NS-632824
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
boiler cycle chemistry, cation conductivity, on-line, process measurement,, ICS Number Code 13.060.60 (Examination of water for physical properties)
Significance and Use | ||||||||||||||||||
5.1 Cation conductivity provides one of the most sensitive and dependable on-line means of detecting anionic contamination in the boiler/steam cycle, such as chlorides, sulfates, nitrates, bicarbonates, and organic acids, such as formic and acetic. 5.2 High sensitivity is provided by intentionally eliminating the pH adjusting treatment chemical(s), for example, ammonia and amines, from the sample and converting remaining salt contaminants into their acid forms which are approximately three times as conductive. 5.3 Guidelines on cation conductivity limits for various cycle chemistry and boiler types have been established by EPRI 5.4 The sample effluent from the cation exchange column also may be used, and in some cases is preferred, for ion chromatography or other anion measurements. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice describes continuous sample conditioning by hydrogen ion exchange and measurement by electrolytic conductivity. It is commonly known as cation conductivity measurement in the power industry although it is actually an indication of anion contamination in high purity water samples. Measurements are typically in a range less than 1 μS/cm. 1.2 The actual conductivity measurements are made using Test Method D5391. 1.3 This practice does not provide for separate determination of dissolved carbon dioxide. Refer to Test Method D4519. 1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-05-07 (Number of items: 2 897 585)
© Copyright 2024 NORMSERVIS s.r.o.