Standard Specification for Perfluoroalkoxy (PFA)-Fluoropolymer Tubing
Translate name
STANDARD published on 1.10.2019
Designation standards: ASTM D6867-19
Publication date standards: 1.10.2019
SKU: NS-972968
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
This specification covers tubing produced from PFA fluoropolymer resins which are cited in another specification. This document specifies tubing dimensional tolerances, tensile properties and related electrical properties as noted in the appropriate tables when tested in accordance with the methods cited. Different tests shall be performed in order to determine the following properties of resins: inside diameter, wall thickness, specific gravity, tensile strength, elongation, and dimensional stability.
Keywords:
extruded material, fluoropolymers, fluoropolymer tubing, melt-processible fluorocarbon polymer, PFA extruded tubing, polytetrafluoroethylene (TFE) copolymers,, ICS Number Code 83.140.99 (Other rubber and plastic products)
1. Scope | ||||||||||||||||
1.1 This specification covers tubing produced from PFA Fluoropolymer resins which are cited in Specification D3307. This document specifies tubing dimensional tolerances, tensile properties and related electrical properties as noted in the appropriate tables when tested in accordance with the methods cited in this specification. This specification is for virgin material only and does not address recycled material, as it is not appropriate for PFA tubing. Note 1: Abbreviations are in accordance with Terminology
D1600.
Note 2: There is no known ISO equivalent to this
standard.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only. 1.3 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||