We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Leak Location using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Conductive Geomembrane Spark Test)
STANDARD published on 1.6.2011
Designation standards: ASTM D7240-06(2011)
Note: WITHDRAWN
Publication date standards: 1.6.2011
SKU: NS-37961
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
geomembrane, leak detection, leak location, electrical leak location method, construction quality assurance, Electrical capacitance technique, Conductive geomembrane spark test, Geomembranes, Leak testing, ICS Number Code 59.080.70 (Geotextiles)
| Significance and Use | ||||
|
Geomembranes are used as barriers to prevent liquids from leaking from landfills, ponds, and other containments. For this purpose, it is desirable that the geomembrane have as little leakage as practical. The liquids may contain contaminants that if released can cause damage to the environment. Leaking liquids can erode the subgrade, causing further damage. Leakage can result in product loss or otherwise prevent the installation from performing its intended containment purpose. Geomembranes are often assembled in the field, either by unrolling and welding panels of the geomembrane material together in the field, or unfolding smaller flexible geomembranes in the field. In exposed geomembrane applications, geomembrane leaks can be caused by poor quality of the subgrade, accidents, poor workmanship, and carelessness. Electrical leak location methods are an effective final quality assurance measure to locate previously undetected leaks. |
||||
| 1. Scope | ||||
|
1.1 This standard is a performance-based practice for using the spark test to electrically locate leaks in exposed geomembranes with an insulating layer that are in intimate contact with a conductive layer. For clarity, this document uses the term ‘leak’ to mean holes, punctures, tears, cuts, cracks and similar breaches over the partial or entire area of an installed geomembrane (as defined in 3.2.3). 1.2 This test method can be used on exposed geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, and other containment facilities. This standard is applicable for geomembranes in direct and intimate contact with a conductive surface or with a conductive layer integrally included. 1.3 SAFETY WARNING: The electrical methods used for geomembrane leak location use high voltage, low current power supplies, resulting in the potential for electrical shock. The electrical methods used for geomembrane leak location should be attempted by only qualified and experienced personnel. Appropriate safety measures must be taken to protect the leak location operators as well as other people at the site. 1.4 This standard does not purport to address all of the safety and liability concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
| 2. Referenced Documents | ||||
|
Historical
1.7.2014
Historical
1.11.2009
Historical
1.5.2013
Historical
1.6.2009
Historical
1.10.2011
Historical
1.7.2010
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-06-18 (Number of items: 2 283 376)
© Copyright 2026 NORMSERVIS s.r.o.