We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Determination of Dioctyl Sulfosuccinate in Sea Water by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
STANDARD published on 1.5.2011
Designation standards: ASTM D7730-11
Note: WITHDRAWN
Publication date standards: 1.5.2011
SKU: NS-39031
The number of pages: 11
Approximate weight : 33 g (0.07 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
Dioctyl Sulfosuccinate , Liquid Chromatography, Mass Spectrometry, Water, ICS Number Code 71.060.50 (Salts)
Significance and Use | ||||||
DOSS is an anionic detergent that is approved by the Food and Drug Administration and is used widely as a laxative, emulsifying, solubilizing and dispersing agent, and is used in the cosmetic industry. DOSS may also be used as a dispersing agent to treat oil. DOSS may be released into the environment at levels that may be harmful to aquatic life. The US EPA aquatic life benchmark for DOSS is 40 ppb. This method has been investigated for use with reagent and sea water. |
||||||
1. Scope | ||||||
1.1 This procedure covers the determination of dioctyl sulfosuccinate (DOSS) in sea water by direct injection using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). This analyte is qualitatively and quantitatively determined by this method. This method adheres to selected reaction monitoring (SRM) mass spectrometry. 1.2 The Detection Verification Level (DVL) and Reporting Range for DOSS are listed in Table 1. 1.2.1 The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 and Fig. 2 display the signal/noise ratio of the selected reaction monitoring (SRM) transition. 1.2.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 5 for DOSS, taking into account the 50% sample preparation dilution factor. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 Detection Verification Level and Reporting Range
|
||||||
2. Referenced Documents | ||||||
|
Historical
1.1.2014
Historical
15.3.2011
Historical
1.4.2012
Historical
1.10.2009
Historical
15.12.2013
Historical
1.4.2008
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2025-05-05 (Number of items: 2 198 283)
© Copyright 2025 NORMSERVIS s.r.o.