Standard Test Method to Assess the Activity of Microbicides against Viruses in Suspension
STANDARD published on 1.10.2011
Designation standards: ASTM E1052-11
Note: WITHDRAWN
Publication date standards: 1.10.2011
SKU: NS-40273
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
cell cultures, microbicide, suspension test, virucidal test, virucide, viruses in suspension: Cytotoxicity, Disinfectants/disinfection, Efficacy, Embryonated eggs, Laboratory environmental analysis, Microbiological examination, Suspension tests, Tissue culture host systems, Virology, ICS Number Code 65.100.01 (Pesticides and other agrochemicals)
Significance and Use | ||||||||||||
This test method is to determine if a test substance can inactivate viruses in suspension. Regulatory agencies may require additional testing using in vitro (Test Methods E1053, E2197) or in vivo (Test Method E1838) carrier tests for product registration purposes. |
||||||||||||
1. Scope | ||||||||||||
1.1 This test method is intended to demonstrate the virucidal activity of test substances with viruses in suspension. 1.2 It is the responsibility of the investigator to determine whether Good Laboratory Practice regulations (GLPs) are required and to follow them where appropriate (40 CFR, Part 160 for EPA submissions and 21 CFR, Part 58 for FDA submissions). 1.3 Refer to the appropriate regulatory agency for performance standards of virucidal efficacy. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The user should consult a reference for the laboratory safety recommendations. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Historical
1.1.2011
Historical
1.10.2009
Historical
1.10.2008
Historical
1.5.2012
Historical
1.10.2012
Historical
1.11.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-04-30 (Number of items: 2 198 114)
© Copyright 2025 NORMSERVIS s.r.o.