Standard Test Method for Temperature and Enthalpy Measurement Validation of Differential Scanning Calorimeters
STANDARD published on 1.12.2011
Designation standards: ASTM E2253-11
Note: WITHDRAWN
Publication date standards: 1.12.2011
SKU: NS-44810
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
detection limit, differential scanning calorimetry, enthalpy, linearity, precision, quantitation limit, range, repeatability, thermal analysis, validation, Calorimeter, Detection method, Differential scanning calorimetry (DSC), Endothermic temperature analysis, Enthalpy, Exothermic temperature analysis, Heat flow, Linear changes/linearity, Quantitation estimate, Repeatability/reproducibility (RR), Thermal analysis (TA), Validation, ICS Number Code 17.200.10 (Heat. Calorimetry)
Significance and Use | ||||||||||||||||
This test method may be used to determine and validate the performance of a particular DSC apparatus. This test method may be used to determine and validate the performance of a particular method based upon a DSC temperature and enthalpic measurement, or both. This test method may be used to determine the repeatability of a particular apparatus, operator, or laboratory. This test method may be used for specification and regulatory compliance purposes. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method provides procedures for validating temperature and enthalpy measurements of differential scanning calorimeters (DSC) and analytical methods based upon the measurement of temperature or enthalpy (or heat), or both, by DSC. Performance parameters determined include temperature and calorimetric repeatability (precision), detection limit, quantitation limit, linearity, and bias. This test method is applicable to exothermic events. 1.2 Validation of apparatus performance and analytical methods is requested or required for quality initiatives or where results may be used for legal purposes. 1.3 The values stated in SI units are to regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historical
1.10.2009
Historical
1.10.2009
Historical
1.10.2008
Historical
1.1.2010
Historical
1.4.2014
Historical
1.10.2013
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-05-17 (Number of items: 2 902 148)
© Copyright 2024 NORMSERVIS s.r.o.