Standard Test Methods for Fire Resistive Grease Duct Enclosure Systems
STANDARD published on 1.5.2004
Designation standards: ASTM E2336-04
Note: WITHDRAWN
Publication date standards: 1.5.2004
SKU: NS-45062
The number of pages: 15
Approximate weight : 45 g (0.10 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
enclosure material, engulfment test, fire-resistive, fire separating elements, grease duct, grease duct enclosure system, hose stream, internal fire test, ICS Number Code 13.220.40 (Ignitability and burning behaviour of materials and products), 21.260 (Lubrication systems)
| 1. Scope | ||||||||||||||||
|
Note 1—The majority of this standard is based on the Model Building Code Evaluation Service Acceptance Criteria titled ACCEPTANCE CRITERIA FOR GREASE DUCT ENCLOSURE ASSEMBLIES, AC101, which was created in 1994. Numerous design listings and labeled materials exist based on the provisions of this standard. 1.1 These test methods evaluate the enclosure materials and the grease duct enclosure systems using the following test methods: noncombustibility, fire resistance, durability, internal fire, and fire-engulfment with a through-penetration fire stop. 1.2 These test methods prescribe a standardized fire exposure for comparing the test results of the enclosure materials and grease duct enclosure systems. The results of these tests are one factor in assessing predicted fire performance of grease duct enclosure systems. Using these test results to predict the performance of actual grease duct enclosure systems requires the evaluation of test conditions. 1.3 The values stated in inch-pound units are to be regarded as the standard. The SI values given in parentheses are for information only. 1.4 The text of these test methods references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the fire test response standard. 1.5 These test methods are used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.6 These test methods do not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of these test methods to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2026-01-26 (Number of items: 2 257 479)
© Copyright 2026 NORMSERVIS s.r.o.