We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Comprehensive Building Asbestos Surveys (Includes all amendments And changes 12/31/2010).
Automatically translated name:
Standard Practice for Comprehensive Building Asbestos Surveys
STANDARD published on 1.7.2004
Designation standards: ASTM E2356-04e1
Note: WITHDRAWN
Publication date standards: 1.7.2004
SKU: NS-45117
The number of pages: 40
Approximate weight : 120 g (0.26 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
ICS Number Code 91.100.40 (Products in fibre-reinforced cement)
| 1. Scope | ||||||||||||||||
|
1.1 This standard practice describes procedures for conducting comprehensive surveys of buildings and facilities for the purpose of locating, identifying, quantifying and assessing asbestos-containing materials. 1.2 The results of a Comprehensive Building Asbestos Survey are intended to be used for ongoing management of asbestos-containing materials, including Operations Maintenance, removal and other response actions. This includes response actions associated with renovations. A Comprehensive Building Asbestos Survey is also intended to provide information required for removal of asbestos-containing materials prior to demolition of a building or facility. 1.3 This standard practice discusses two types of surveys: Baseline Surveys and Project Design Surveys. 1.4 This standard practice discusses the following activities for each of the above types of surveys: 1.4.1 Planning the survey to meet defined objectives; 1.4.2 Obtaining and reviewing information on the building or facility including previous surveys and response actions; 1.4.3 Conducting the physical activities of inspecting the premises and collecting bulk samples of suspect materials; 1.4.4 Analyzing the bulk samples for asbestos type and content; 1.4.5 Assessing the Current Condition and Potential for Disturbance of asbestos-containing materials; and 1.4.6 Preparing a report that includes a narrative discussion of the findings, tabulations of inspection, sampling and analysis results, graphical depiction of the areas inspected, and the results of the assessment. 1.5 A Comprehensive Building Asbestos Survey provides sufficient information about the asbestos-containing materials in a building or facility for purposes of a real property transaction. In situations where the amount of information required by a party to the transaction is minimal, a Limited Asbestos Screen may suffice in place of the Comprehensive Building Asbestos Survey. 1.6 This standard practice does not include air sampling or surface (dust) sampling for purposes of evaluating a potential exposure hazard from airborne asbestos fibers. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2026-01-26 (Number of items: 2 257 479)
© Copyright 2026 NORMSERVIS s.r.o.