Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs
STANDARD published on 1.10.2011
Designation standards: ASTM E2461-05(2011)
Note: WITHDRAWN
Publication date standards: 1.10.2011
SKU: NS-45353
The number of pages: 17
Approximate weight : 51 g (0.11 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
annealed glass, deflection, flat glass, glass, insulating glass, laminated glass, load resistance, monolithic glass, probability of breakage, strength, wind load, ICS Number Code 81.040.20 (Glass in building)
1. Scope | ||||||||||
1.1 This practice covers the determination of the thickness of glass installed in airport traffic control towers (ATCT) to resist a specified design loading with a selected probability of breakage less than or equal to either 1 lite per 1000 or 4 lites per 1000 at the first occurrence of the design wind loading. 1.2 The procedures apply to common outward sloping cab glass designs for which the specified loads do not exceed 10 kPa (210 psf). 1.3 The procedures assume control tower cab glass has an aspect ratio no greater than 2. 1.4 The procedures assume control tower cab glass has an area no less than 1.86 square metres (20 square feet). 1.5 The procedures apply only to annealed monolithic, annealed laminated, or annealed insulating glass having a rectangular or trapezoidal shape. 1.6 The use of the procedures assumes the following: 1.6.1 Annealed monolithic and annealed laminated glass installed in ATCTs shall have continuous lateral support along two parallel edges, along any three edges, or along all four edges; 1.6.2 Insulating glass shall have continuous lateral support along all four edges; and 1.6.3 Supported glass edges are simply supported and free to slip in plane. 1.7 The procedures do not apply to any form of wired, patterned, etched, sandblasted, or glass types with surface treatments that reduce the glass strength. 1.8 The procedures do not apply to any form of heat treated glass, chemically strengthened glass, or any type of glass with surface treatments intended to increase the glass strength. 1.9 The procedures address the determination of thickness and construction type to resist a specified design wind load at a selected probability of breakage. The final glass thickness and construction determined also depends upon a variety of other factors (see ). 1.10 These procedures do not address blast loading on glass. 1.11 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2025-09-12 (Number of items: 2 232 097)
© Copyright 2025 NORMSERVIS s.r.o.