Standard Practice for the Measurement of the Apparent Attenuation of Longitudinal Ultrasonic Waves by Immersion Method
STANDARD published on 1.1.2005
Designation standards: ASTM E664-93(2005)
Note: WITHDRAWN
Publication date standards: 1.1.2005
SKU: NS-47580
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
apparent attenuation, attenuation, immersion method, nondestructive examination, ultrasonic examination, ICS Number Code 17.140.01 (Acoustic measurements and noise abatement in general)
Significance and Use | ||||||
The measurement of apparent attenuation in materials is useful in applications such as the comparison of heat treatments of different lots of material or the assessment of the degradation of materials due to environment. Several different modes of wave vibration can be propagated in solids. This practice is concerned with the attenuation associated with longitudinal waves introduced into the specimen by the immersion method. This practice allows for the comparison of the apparent attenuations of geometrically similar specimens. For the determination of apparent attenuation, the procedures described herein are valid only for measurements in the far field of the ultrasonic beam. |
||||||
1. Scope | ||||||
1.1 This practice describes a procedure for measuring the apparent attenuation of ultrasound in materials or components with flat, parallel surfaces using conventional pulse-echo ultrasonic flaw detection equipment in which reflected indications are displayed in an A-scan presentation. 1.2 The measurement procedure is readily adaptable for the determination of relative attenuation between materials. For absolute (true) attenuation measurements, indicative of the intrinsic nature of the material, it is necessary to correct for specimen geometry, sound beam divergence, instrumentation, and procedural effects. These results can be obtained with more specialized ultrasonic equipment and techniques. 1.3 The values stated in inch-pound units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||