Standard Practice for Emergency Joining of Booms with Incompatible Connectors
STANDARD published on 1.4.2007
Designation standards: ASTM F1657-96(2007)
Note: WITHDRAWN
Publication date standards: 1.4.2007
SKU: NS-51062
The number of pages: 3
Approximate weight : 9 g (0.02 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
boom, boom connector, connector, incompatible boom connector, oil spill responses, ICS Number Code 23.020.10 (Stationary containers and tanks)
Significance and Use | ||||||||
The use of this practice for the emergency joining of booms will not guarantee the effective performance of the joined boom sections, since each boom design and the environmental conditions of each incident govern the overall performance. Historically, different types of end connectors have been produced. This practice addresses the operational need to connect different types, during spill incidents. (Warning—Use of this practice with similar or different sizes of boom may cause the transmission of unwanted loading such as, tension loading and bending moments on certain boom parts resulting in possible premature failure of the containment system.) There are a wide range of boom connector configurations presently in use. These connectors were based upon some or all of the following design criteria: 3.3.1 Connect and transfer tensile loads between boom sections, 3.3.2 Minimize oil leakage between boom sections, 3.3.3 Be easily connectable in the presence of dirt, oil or ice, or a combination thereof, 3.3.4 Be quickly and easily connected and disconnected, in and out of the water, 3.3.5 Maintain boom performance (freeboard, heave response, conformance, stability, and so forth), 3.3.6 Be unaffected by temperature extremes, 3.3.7 Have no protruding parts that could snag, injure, or puncture, 3.3.8 Be light weight and buoyant, 3.3.9 Be operatively symmetrical, 3.3.10 Require no special tools for installation or removal, 3.3.11 Require no loose parts for connection, 3.3.12 Extend to the full height and draft of the boom, 3.3.13 Resist distortion (that is, winding boom on a reel), and 3.3.14 Be inherently safe to personnel. |
||||||||
1. Scope | ||||||||
1.1 This practice provides a standard practice for the joining of oil spill containment boom connectors in emergencies. 1.2 The use of this connection method may adversely affect the total tensile strength of the connected booms. 1.3 These criteria are intended to define mating requirements that will allow the emergency or occasional connection of unlike connectors. 1.4 This practice is not intended to replace Specification F 962. 1.5 This practice does not address the compatibility of spill control equipment with spill products. It is the user's responsibility to ensure that any equipment selected is compatible with the anticipated spilled material. 1.6 There is no guarantee that all of the connectors in use today can accept the holes spaced as required without interfering with existing bolt holes or other connector features. 1.7 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see 3.2. |
||||||||
2. Referenced Documents | ||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-05-19 (Number of items: 2 902 277)
© Copyright 2024 NORMSERVIS s.r.o.