Standard Guide for Measurement of pH Below Resilient Flooring Installations
Translate name
STANDARD published on 15.3.2023
Designation standards: ASTM F3441-23
Note: WITHDRAWN
Publication date standards: 15.3.2023
SKU: NS-1136879
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
alkali, carbonation, pH, reagent water,, ICS Number Code 91.060.30 (Ceilings. Floors. Stairs),97.150 (Floor coverings)
Significance and Use |
4.1?There is typically a higher concentration of soluble alkali salts in the surface region of a concrete slab due to the initial bleeding process of a freshly placed concrete slab. If after a resilient floor covering material is installed there is sufficient moisture within the slab to place these salts into solution a potentially damaging high pH solution can develop beneath the installed material. 4.2?Results obtained through the use of this guide indicate the comparative pH of reagent water placed on properly prepared concrete slab surfaces only at the time of the procedure and in the specific locations evaluated. 4.3?If pre-installation surface pH evaluation is required by the manufacturer of the resilient flooring, adhesive, patching/underlayment products or project specifications, their instructions and limitations should be consulted. |
1. Scope |
1.1?This guide discusses procedures that may be used for evaluating the comparative change in pH of reagent water placed on the surface of a properly prepared concrete slab surface. 1.2?This guide is intended to be used in conjunction with the flat surface electrode pH meter manufacturers calibration procedures, operation instructions, and interpretive data where available. 1.3?This guide is intended to be used in conjunction with the pH paper manufacturers instructions, product shelf life, and interpretive data where available. 1.4?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use 1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |