Standard Test Methods for Determining Radiopacity for Medical Use
STANDARD published on 1.3.2007
Designation standards: ASTM F640-07
Note: WITHDRAWN
Publication date standards: 1.3.2007
SKU: NS-55981
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
implants, radiopacity, surgical applications, surgical devices, surgical implants, test methods, X-ray, ICS Number Code 11.120.01 (Pharmaceutics in general), 83.080.01 (Plastics in general)
Significance and Use | ||||||||||
These methods are intended to determine whether a material, product, or part of a product has the degree of radiopacity desired for its application as a medical device in the human body. These methods allow for both qualitative and quantitative evaluation in different comparative situations. |
||||||||||
1. Scope | ||||||||||
1.1 These test methods cover the determination of the radiopacity of materials and products utilizing X-ray based techniques, including fluoroscopy, angiography, CT (computed tomography) and DEXA, also known as DXA, (dual energy X-ray absorptiometry). The results of these measurements are an indication of the likelihood of locating the product within the human body. 1.2 Types of Tests - There are three methods of tests described, differing in the method of determining radiopacity. 1.2.1 Method A - Radiopacity is (1) qualitatively determined by viewing image(s) of a test sample and the image background, with or without the use of a body mimic, or ( 2) quantitatively determined as a specific difference in optical density or pixel intensity between the image of a test sample and the image background, with or without the use of a body mimic. 1.2.2 Method B - Radiopacity is determined by (1) qualitatively comparing image(s) of a test sample and a user-defined standard without the use of a body mimic, or (2) quantitatively determining the specific difference in optical density or pixel intensity between the image of a test sample and the image of a user-defined standard without the use of a body mimic. 1.2.3 Method C - Radiopacity is determined by (1) qualitatively comparing image(s) of a test sample and a user-defined standard with the use of body mimic or (2) quantitatively determining the specific difference in optical density or pixel intensity between the image of a test sample and the image of a user-defined standard with the use of a body mimic. 1.3 The values stated in SI units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-05-07 (Number of items: 2 897 585)
© Copyright 2024 NORMSERVIS s.r.o.