Standard Practice for Use of a Radiochromic Film Dosimetry System
STANDARD published on 1.6.2012
Designation standards: ASTM/ISO 51275-13
Publication date standards: 1.6.2012
SKU: NS-869
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
absorbed dose, dose, dosimeter, dosimetry system, electron beam, gamma radiation, ionizing radiation, irradiation, radiation, radiation processing, radiation sterilization, radiochromic film, ICS Number Code 17.240 (Radiation measurements), 37.040.25 (Radiographic films)
Significance and Use |
The radiochromic film dosimetry system provides a means for measuring absorbed dose based on radiation-induced change in color using spectrophotometers, densitometers or scanned images. Radiochromic film dosimetry systems are commonly used in industrial radiation processing, for example in the sterilization of medical devices and the irradiation of foods. |
1. Scope |
1.1 This is a practice for using radiochromic film dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. Radiochromic film dosimetry systems are generally used as routine dosimetry systems. 1.2 The radiochromic film dosimeter is classified as a Type II dosimeter on the basis of the complex effect of influence quantities. See ASTM Practice E2628. 1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for a radiochromic film dosimetry system. It is intended to be read in conjunction with ASTM E2628. 1.4 This practice covers the use of radiochromic film dosimetry systems under the following conditions: 1.4.1 The absorbed dose range is 1 Gy to 150 kGy. 1.4.2 The absorbed dose rate is 1 × 10-2 to 1 × 1013 Gy·s-1 (1-4). 1.4.3 The photon energy range is 0.1 to 50 MeV. 1.4.4 The electron energy range is 70 keV to 50 MeV. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |