Standard CISPR 16-1-5-ed.2.0 17.12.2014 preview

CISPR 16-1-5-ed.2.0

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz



STANDARD published on 17.12.2014


Language
Format
AvailabilityIN STOCK
Price496.10 USD excl. VAT
496.10 USD

The information about the standard:

Designation standards: CISPR 16-1-5-ed.2.0
Publication date standards: 17.12.2014
SKU: NS-116251
The number of pages: 192
Approximate weight : 607 g (1.34 lbs)
Country: International technical standard
Category: Technical standards CISPR

The category - similar standards:

EmissionImmunity

Annotation of standard text CISPR 16-1-5-ed.2.0 :

CISPR 16-1-5:2014 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites that are used for the validation of compliance test sites in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107. Measurement instrumentation specifications are given in CISPR 16-1-1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4, which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements. This second edition cancels and replaces the first edition published in 2003, and its Amendment 1 (2012). It constitutes a technical revision which includes the following significant technical changes with respect to the previous edition: - site validation methods for other sites covered in CISPR 16-1-6 are added; - smaller step sizes are specified for swept frequency measurements; - the minimum ground plane size is increased; - and other miscellaneous technical and editorial refinements are included. Keywords: electromagnetic compatibility The contents of the corrigendum 1 of August 2020 have been included in this copy. La CISPR 16-1-5:2014 specifie les exigences relatives aux emplacements detalonnage dans la gamme de frequences comprise entre 5 MHz et 18 GHz utilisee pour etalonner lantenne conformement a la CISPR 16-1-6. Elle specifie egalement les exigences relatives aux emplacements dessai de reference utilises pour valider les emplacements dessais de conformite dans la gamme de frequences comprises entre 30 MHz et 1 000 MHz conformement a la CISPR 16-1-4. Elle a le statut de Norme fondamentale en CEM en accord avec le Guide 107 de lIEC. Les specifications de linstrumentation de mesure sont donnees dans la CISPR 16-1-1 et la CISPR 16-1-4. Des informations supplementaires et generales sur les incertitudes sont donnees dans la CISPR 16-4, qui peut egalement etre utile pour etablir les estimations de lincertitude pour les processus detalonnage des antennes et les mesures de validation demplacement. Cette seconde edition annule et remplace la premiere edition publiee en 2003 et son Amendement 1 (2012). Elle constitue une revision technique qui inclut les modifications techniques majeures suivantes par rapport a ledition precedente: - des methodes de validation dautres emplacements couverts dans le CISPR 16-1-6 sont ajoutees; - des tailles de pas plus petites sont specifiees pour les mesures par balayage de frequence; - la dimension minimale du plan de sol a ete augmentee; - et dautres ameliorations techniques et editoriales diverses sont incluses. Mot cle: compatibilite electromagnetique Le contenu du corrigendum 1 daout 2020 a ete pris en consideration dans cet exemplaire.

These changes apply to this standard:

CISPR 16-1-5-ed.2.0/Amd.1 Change

Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
(Amendement 1 - Specification des methodes et des appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Partie 1-5: Appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Emplacements d´etalonnage d´antenne et emplacements d´essai de reference pour la plage comprise entre 5 MHz et 18 GHz)

Change published on 16.12.2016

Selected format:

Show all technical information.
13.20 USD


IN STOCK

These corrections apply to this standard:

CISPR 16-1-5-ed.2.0/Cor.1 Correction

Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
(Corrigendum 1 - Specification des methodes et des appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Partie 1-5: Appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Emplacements d´etalonnage d´antenne et emplacements d´essai de reference pour la plage comprise entre 5 MHz et 18 GHz)

Correction published on 31.8.2020

Selected format:

Show all technical information.
1.30 USD


IN STOCK

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.