Test methods for determining the contribution to the fire resistance of structural members - Part 11: Applied reactive protection to solid steel bars in tension based on mechanically loaded fire tests
Translate name
STANDARD published on 1.11.2026
Designation standards: ČSN EN 13381-11
Classification mark: 730858
Catalog number: 524526
Publication date standards: 1.11.2026
SKU: NS-1289040
Approximate weight : 295 g (0.65 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
This document describes the test and assessment procedure for determining the contribution of re-active fire protection systems to the fire resistance of solid steel bars used as tension bars, when exposed to the standard temperature/time curve specified in EN 1363-1. In special circumstances, where specified in National Building Regulations, there can be a need to subject reactive fire protection systems to a slow heating curve (smouldering fire) as defined in EN 1363-2. The corresponding test and assessment procedure are described in Annex E. The fire protection performance is determined by mechanically loaded steel bars usually fire tested in horizontal orientation. Information regarding the testing of additional unloaded specimens is given to assess the influence of the bar orientation and smouldering fire behaviour.
The principles of the testing and assessment procedure can also be applied for other profile types. This document does not include steel bars used as reinforcement in concrete construction.
This document is applicable to steel bars up to a maximum diameter of 130 mm. In the case of rectangular bars, the maximum edge length is limited to 130 mm with a maximum aspect ratio of 2:1 against the shorter edge length.
The test programme and the assessment are designed to cover:
This document also provides the assessment procedure, which prescribes how the analysis of the test data are made and gives guidance on the procedures by which interpolation is undertaken. The assessment procedure is used to establish:
The limits of applicability of the results of the assessment arising from the fire test are defined together with permitted direct application of the results to different steel grades, steel types and profile dimensions over the range of dry film thicknesses of the applied reactive fire protection system tested