ČSN EN 17082 (061910)

Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW

Translate name

STANDARD published on 1.4.2020


Language
Format
AvailabilityIN STOCK
Price52.80 USD excl. VAT
52.80 USD

The information about the standard:

Designation standards: ČSN EN 17082
Classification mark: 061910
Catalog number: 509193
Publication date standards: 1.4.2020
SKU: NS-989602
The number of pages: 196
Approximate weight : 619 g (1.36 lbs)
Country: Czech technical standard
Category: Technical standards ČSN

The category - similar standards:

Gas heaters

Annotation of standard text ČSN EN 17082 (061910):

This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances". This document also applies to warm air heaters having forced draught burners. This document applies to Type A2, A3 appliances, with an input not exceeding 300 kW (net CV basis), intended for non-domestic use. This document also applies to Type B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net CV basis), intended for domestic and non-domestic use. Provision of the heated air may be by means of ducting. This document does not apply to: a) dual purpose air conditioning appliances (heating and cooling); b) appliances where the air is heated by an intermediate fluid; c) portable or transportable forced convection appliances; d) appliances fitted with manual or automatic means of adjusting the combustion products evacuation by means of flue dampers; e) appliances having multiple heating units with a single draught diverter; f) appliances fitted with more than one flue outlet; g) appliances fitted with gas boosters; h) C21 and C41 appliances for 3rd family gases. NOTE - For C41 appliances, see all requirements and test methods that are valid for C21 appliances, unless otherwise stated. This document is not intended to cover appliances projected for connection to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance. This document is applicable to appliances which are intended to be type tested

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.