We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Eurocode 3 - Design of steel structures - Part 1-7: Plate assemblies with elements under transverse loads
Translate name
STANDARD published on 1.10.2025
Designation standards: ČSN EN 1993-1-7-ed.2
Classification mark: 731401
Catalog number: 521584
Publication date standards: 1.10.2025
SKU: NS-1241305
The number of pages: 84
Approximate weight : 283 g (0.62 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
provides rules for the structural design of assemblies of unstiffened and stiffened steel plates whose elements are under predominantly distributed transverse loads.
2) EN 1993-1-7 is applicable to containment structures such as silos, tanks, digesters and lock gates, where the external actions chiefly act transversely on their individual plates or panels. Where a plate or panel under bending is additionally subject to membrane forces that have a significant effect on the resistance, this document covers assessment of the resistance through its computational analysis procedures.
3) EN 1993-1-7 is applicable to structures with rectangular, trapezoidal or triangular component plate segments, each with one axis of symmetry.
4) EN 1993-1-7 does not apply to plates or panels where the dominant structural resistance require-ment relates to membrane forces in the plates (for these, see EN 1993-1-5).
5) EN 1993-1-7 does not apply to plates or panels whose curvature (out of flatness) exceeds that defined in 1.1(12). For such curved plates, see EN 1993-1-6.
6) EN 1993-1-7 does not apply to circular or annular plates. For such plates, see EN 1993-1-6.
7) EN 1993-1-7 does not apply to cold-formed sheeting. For such plates, see EN 1993-1-3.
8) This document is only concerned with the requirements for design of plates and plate assemblies against the ultimate limit states of:
12) Where no application part defines a different range, this document applies to structures within the following limits:
Single plate elements are treated as flat where the deviation from flatness e0 meets the condition (see Figure 9.1). Where this criterion is not met, the plate or plate assembly is considered to be a shell panel (see EN 1993-1-6). 00,750et<=
Assumptions:
2) The design methods given in EN 1993-1-7 are applicable if:
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-10-20 (Number of items: 2 239 217)
© Copyright 2025 NORMSERVIS s.r.o.