We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
District heating pipes - Bonded single pipe systems for directly buried hot water networks - Factory made fitting assemblies of steel service pipes, polyurethane thermal insulation and a casing of polyethylene
Translate name
STANDARD published on 1.6.2025
Designation standards: ČSN EN 448
Classification mark: 383372
Catalog number: 521486
Publication date standards: 1.6.2025
SKU: NS-1221919
Approximate weight : 108 g (0.24 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
This document specifies requirements and test methods for factory made thermally insulated bonded fitting assemblies for hot water networks in accordance with EN 13941-1, comprising a steel service pipe, in most cases a steel fitting, polyurethane (PUR) foam thermal insulation and a casing of polyethylene.
The fitting assembly can also include the following additional elements: measuring wires, spacers and diffusion barriers.
This document specifies the characteristics of the following fitting assemblies:
This document applies to fitting assemblies with a design pressure of at least 1,6 MPa
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-06-05 (Number of items: 2 203 778)