ČSN EN IEC 60601-2-1-ed.3 (364801)

Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV

Translate name

STANDARD published on 1.9.2021


Language
Format
AvailabilityIN STOCK
Price39.90 USD excl. VAT
39.90 USD

The information about the standard:

Designation standards: ČSN EN IEC 60601-2-1-ed.3
Classification mark: 364801
Catalog number: 512563
Publication date standards: 1.9.2021
SKU: NS-1034783
The number of pages: 124
Approximate weight : 403 g (0.89 lbs)
Country: Czech technical standard
Category: Technical standards ČSN

The category - similar standards:

Therapy equipment

Annotation of standard text ČSN EN IEC 60601-2-1-ed.3 (364801):

This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for TREATMENT of PATIENTS. This particular standard, with the inclusion of TYPE TESTS and SITE TESTS, applies to the manufacture and some installation aspects of ELECTRON ACCELERATORS and their included equipment used to increase the precision, accuracy and volumetric targeting of the TREATMENT delivery intended for RADIOTHERAPY in medical practice, including those in which the selection and DISPLAY of TREATMENT PARAMETERS can be controlled automatically by PROGRAMMABLE ELECTRONIC SUBSYSTEMS (PESS), that, under NORMAL CONDITIONS and in NORMAL USE, deliver a RADIATION BEAM of X-RADIATION or ELECTRON RADIATION having - NOMINAL ENERGY in the range 1 MeV to 50 MeV, - maximum ABSORBED DOSE RATES between 0,001 Gy × s-1 and 1 Gy × s-1 at the ERP from the RADIATION SOURCE, and - REFERENCE TREATMENT DISTANCES (RTDs) between 0,5 m and 2 m from the RADIATION SOURCE; and intended to be - for NORMAL USE, operated under the authority of the RESPONSIBLE ORGANIZATION by QUALIFIED PERSONS appropriately licensed or having the required skills for a particular medical application, for particular SPECIFIED clinical purposes, - maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE, AND - subject to regular QUALITY ASSURANCE performance and calibration checks by a QUALIFIED PERSON

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.