Standard IEC 60060-1-ed.4.0-RLV 17.4.2025 preview

IEC 60060-1-ed.4.0-RLV

High-voltage test techniques - Part 1: General terminology and test requirements

Translate name

STANDARD published on 17.4.2025


Language
Format
AvailabilityIN STOCK
Price906.00 USD excl. VAT
906.00 USD

The information about the standard:

Designation standards: IEC 60060-1-ed.4.0-RLV
Publication date standards: 17.4.2025
SKU: NS-1219849
The number of pages: 263
Approximate weight : 820 g (1.81 lbs)
Country: International technical standard
Category: Technical standards IEC

The category - similar standards:

Measurement of electrical and magnetic quantities

Annotation of standard text IEC 60060-1-ed.4.0-RLV :

IEC 60060-1:2025 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60060-1:2025 is applicable to: - dielectric tests with direct voltage; - dielectric tests with alternating voltage; - dielectric tests with impulse voltage; - dielectric tests with combinations of the above. This document is applicable to tests on equipment having its highest voltage for equipment Um above 1,0 kV AC and 1,5 kV DC. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - The general layout and text have been updated and improved to make the standard easier to use, particularly the clauses for combined and composite test voltages. - The positive tolerance of the front time of lightning impulse voltage has been extended for Um > 800 kV to 100 % (= 2,4 µs). - For switching impulse voltage, a front time has been introduced, similar to lightning impulse voltage and with the new front time the standard switching impulse is defined as 170/2 500 µs. - The requirements for precipitations have been adjusted depending on Um. - A new Annex C, "Procedure for manual calculation from graphical waveforms" has been incorporated. - No examples of software have been given in Annex D, "Guidance for implementing software for evaluation of lightning impulse voltage parameters". - The annex relating to the "Background to the introduction of the test voltage factor for evaluation of impulses with overshoot" has been deleted. - A new informative Annex F, "New definition of the front time of switching impulse voltage" has been incorporated. NOTE 1 Alternative test procedures can be required to obtain reproducible and significant results. The choice of a suitable test procedure is considered by the relevant Technical Committee. NOTE 2 For voltages Um above 800 kV it is possible that some specified procedures, tolerances and uncertainties will not be achievable.

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.