Specifications for particular types of winding wires - Part 27-4: Paper tape covered rectangular aluminium wire
Translate name
STANDARD published on 13.6.2024
Designation standards: IEC 60317-27-4-ed.1.1+Amd.1-CSV
Publication date standards: 13.6.2024
SKU: NS-1187378
The number of pages: 22
Approximate weight : 66 g (0.15 lbs)
Country: International technical standard
Category: Technical standards IEC
IEC 60317-27-4:2020+AMD1:2024 CSV specifies the requirements of paper tape covered rectangular aluminium winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is: - width: min. 2,00 mm max. 16,0 mm; - thickness: min. 0,80 mm max. 5,60 mm. The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5.