We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Medical electrical equipment - Part 1-10: General requirements for basic safety and essential performance - Collateral Standard: Requirements for the development of physiologic closed-loop controllers
Translate name
STANDARD published on 22.7.2020
Designation standards: IEC 60601-1-10-ed.1.2+Amd.1+Amd.2-CSV
Publication date standards: 22.7.2020
SKU: NS-1094317
The number of pages: 173
Approximate weight : 550 g (1.21 lbs)
Country: International technical standard
Category: Technical standards IEC
IEC 60601-1-10:2007+A1:2013+A2:2020 Specifies requirements for the development (analysis, design, verification and validation) of a physiologic closed-loop controller (PCLC) as part of a physiologic closed-loop control system (PCLCS) in medical electrical equipment and medical electrical systems to control a physiologic variable. This collateral standard applies to various types of PCLC, e.g. linear and non-linear, adaptive, fuzzy, neural networks. This collateral standard applies to a closed-loop controller that sets the controller output variable in order to adjust (i.e., change or maintain) the measured physiologic variable by relating it to the reference variable. This consolidated version consists of the first edition (2007), its amendment 1 (2013) and its amendment 2 (2020). Therefore, no need to order amendments in addition to this publication. LIEC 60601-1-10:2007+A1:2013+A2:2020 Specifie les exigences pour le developpement (analyse, conception, verification et validation) dun regulateur physiologique en boucle fermee (RPBF) en tant que partie dun systeme physiologique de commande en boucle fermee (SPCBF) dans les appareils em et les systemes em pour la commande dune variable physiologique. La presente norme collaterale sapplique aux differents types de RPBF, par exemple lineaire et non-lineaire, adaptatifs, fuzzy, reseaux de neurones. La presente norme collaterale sapplique a un regulateur en boucle fermee qui regle la variable de sortie du regulateur afin dajuster (cest-a-dire, changer ou maintenir) la variable physiologique mesuree en effectuant une comparaison avec la variable de reference. Cette version consolidee comprend la premiere edition (2007), son amendement 1 (2013) et son amendement 2 (2020). Il nest donc pas necessaire de commander les amendements avec cette publication.
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2026-07-10 (Number of items: 2 286 359)
© Copyright 2026 NORMSERVIS s.r.o.