Standard ISO 27186:2020-ed.2.0 30.11.2020 preview

ISO 27186:2020-ed.2.0

Active implantable medical devices — Four-pole connector system for implantable cardiac rhythm management devices — Dimensional and test requirements

Translate name

STANDARD published on 30.11.2020


Language
Format
AvailabilityIN STOCK
Price347.40 USD excl. VAT
347.40 USD

The information about the standard:

Designation standards: ISO 27186:2020-ed.2.0
Publication date standards: 30.11.2020
SKU: NS-1011405
The number of pages: 81
Approximate weight : 274 g (0.60 lbs)
Country: International technical standard
Category: Technical standards ISO

The category - similar standards:

Implants for surgery, prosthetics and orthotics

Annotation of standard text ISO 27186:2020-ed.2.0 :

Description / Abstract: This document specifies a four-pole connector system for implantable cardiac rhythm management (CRM) devices which have pacing, electrogram sensing and/or defibrillation functions. This document includes requirements for the connector portion of an implantable lead as well as for the mating connector cavity attached to an implantable pulse generator. Essential dimensions and performance requirements are specified together with appropriate test methods. NOTE The safety, reliability, biocompatibility, biostability and function of any particular part are the responsibility of the manufacturer. This document is not intended to replace or provide alternatives for unipolar or bipolar connector standards that currently exist (such as ISO 11318 and ISO 5841-3). This document is not applicable to high-voltage systems with intended outputs greater than 1 000 V and/or 50 A. This document is not applicable to systems which include sensors or unique electrodes that are not capable of conventional pacing, electrogram sensing and/or defibrillation functions. This document does not specify all connector features. This document does not address all aspects of functional compatibility, safety or reliability of leads and pulse generators assembled into a system. NOTE Lead and pulse generator connector systems not conforming to this document can be safe and reliable and can have clinical advantages.

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.