Standard Practice for Installing Factory-Made Corrugated Aluminum Culverts and Storm Sewer Pipe
STANDARD published on 1.5.2014
Designation standards: ASTM B788/B788M-09(2014)
Note: WITHDRAWN
Publication date standards: 1.5.2014
SKU: NS-8124
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
aluminum pipe, corrugated aluminum pipe, culvert, installation&mdash,underground, joining systems, sewers, ICS Number Code 91.140.80 (Drainage systems)
Significance and Use | ||||||||||||||||
4.1 Corrugated aluminum pipe functions structurally as a flexible ring which is supported by and interacts with the compacted surrounding soil. The soil constructed around the pipe is thus an integral part of the structural system. It is therefore important to ensure that the soil structure or backfill is made up of acceptable material and is well-constructed. Field verification of soil structure acceptability using Test Methods D1556, D2167, D2937, or D6938 as applicable, and comparing the results with Test Method D698 in accordance with the specifications for each project, is the most reliable basis for installation of an acceptable structure. The required density and method of measurement are not specified by this practice, but they must be established in the specifications for each project. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice describes procedures, soils, and soil placement for the proper installation of corrugated aluminum culverts and storm sewers in either trench or projection installations. A typical trench installation is shown in 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.2.1 SI Units—SI units are shown in the text in brackets, and they are the applicable values for metric installation. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historical
1.6.2013
Historical
1.5.2011
Historical
1.12.2010
Historical
1.8.2011
Historical
1.2.2011
Historical
1.5.2011
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-04-26 (Number of items: 2 896 057)
© Copyright 2024 NORMSERVIS s.r.o.